  bcd . 002 8 5 _ aa_ september - 18 - 2013 1 www.power - one.com data sheet ? instrumentation ? li ghting ? industrial applications ? test and measurement ? robotics ? renewable energy ? data comm. ? applied computing ? process control ? wireless abc 300 series 3 00 w ac/dc ? 200 w convection cooled ? - 20 to 50 deg c full load operation ? 3 x 5 x 1.5 (76.2 x 127 x 38.1 mm) ? no minimum load required ? 12 v fan & 5 v standby outputs ? inhibit and power good signals ? conducted emi en 55022 - b, fcc part 15 level b ? ite safety agency approvals ? rohs compliant features applications
abc 300 series 2 www.power - one.com data sheet technical dat a : input parameter description/condition input voltage range universal input 90 - 264 vac 120 C 390 vdc input frequency range 47 - 63 hz input surge current 230 vac (cold start) 65 a max. safety ground leakage current 230 vac 300 a max input current 120 vac @ 200 w 230 vac @ 200 w 3.2 a 1.65 a output parameter description/condition voltage adjustment v1 3% transient response main output 50 to 100% load change, 50 hz, 50% duty cycle, 0.1 a / usec, 50/60 hz. < 10%, recovery time < 5 msec over voltage protection v1 110 to 150% rated max over current protection rated output current 110 to 150% typical short circuit protection automatic recovery over temperature protection automatic recovery 110 c primary heatsink set point tolerance 1% rise time <100 msec ordering information product family volts (vdc) max load convection ( 2 ) max load 300 lfm ( 2 ) minimum load (a) ripple & noise (4) connector total regulation abc300 - 1 t 05g 5 28.0 a 40.0 a 0 2% screw terminal 2.5% abc300 - 1 t 12g 12 15.0 a 25.0 a 0 2% screw terminal 2.5% abc300 - 1 t 15g 15 12.0 a 20.0 a 0 2% screw terminal 2.5% abc300 - 1 t 24g 24 7.5 a 13.54 a 0 2% screw terminal 2.5% abc300 - 1 t 30g 30 6.0 10.83 a 0 2% screw terminal 2.5% abc300 - 1 t 48g 48 3.75 a 6.77 a 0 2% screw terminal 2.5% vfan (all models) 12 0.5 a 0.5 a 0 20% v s/b (all models) 5 2.0 a 2.0 a 0 5% notes: 1. peak current rating of 120% of max, < 30 sec with max of 10% duty cycle. 2. combined power from main output, vfan and vs/b should not exceed total power rating. 3. fan output tolerance is 20% . when v1 full load, vfan needs 20 ma load to be within regulation specification. peak current for fan output is 1 a. 4. ripple is 2% up to 20 % load an d less than 1% above 20% load. output noise measurement is made with a 20 mhz bandwidth using a 6 twisted pair, terminated with a 10 uf tantalum capacitor in parallel with a 0.1 uf ceramic capacitor. 5. specifications are for nominal input voltage, 25 c and max load unless otherwise stated.
bcd . 002 8 5 _ aa_ september - 18 - 2013 3 www.power - one.com data sheet 6. class 1 models have earthing tab j4. class 2 models ( - 2 suffix) have no earthing tab. 7. derate power linearly to 80% from 90 vac to 80 vac input. 8. pow er supply shipped with j3 pin 1 and 2 shorted to enable main output 9. specifications subject to change without notice. 10. air flow over long edge (either direction) required for air flow rating. see mechanical drawing below. 11. warranty 2 years. general specific ations parameter description/condition hold up time 120 vac 10 msec 230 vac 10 msec mtbf >250 khrs bellcore tr - 332 switching frequency pfc converter 80 khz typical resonant converter: variable 35 to 250 khz, 90 khz typical isolation voltage min 5900 vdc input to output weight 450 g (0.99 lbs) environmental parameter description/condition operating temperature operating - 20 to 70 c . see derating charts below . storage - 40 to +85 c . altitude operating 10,000 ft. non - operation 40,000 ft. conducted emissions: en55022, fcc part 15 level b radiated emissions en55022, fcc part 15 level b to be controlled in end system electromagnetic susceptibility en61000 - 4 3 2, 3, 4, 5 level 3 harmonic current en61000 - 3 - 2, class d signals parameter description/condition power good ttl signal goes high after mai n output is within regulation, delay is 0.1 to 0.3 sec inhibit to turn on power supply short j3 pin 1 to j3 pin 2 or j3 pin 7 remote sense compensates for 200 mv drop safety parameter description/condition en / ul / csa en60950 - 1+a12:2011, iec60950 - 1 2 nd +a1 2009, csa - 22.2 no 60950 - 01 - 07+ a1, ul60950 - 1 - 2011
abc 300 series 4 www.power - one.com data sheet figure 1 output power vs. temperature figure 2 dimension drawing (top and side view)
bcd . 002 8 5 _ aa_ september - 18 - 2013 5 www.power - one.com data sheet mechanical input = j1 earthing tab = j4 dc output = j2 signals & aux power= j3 pin 1: ac line pin 2: ac neutral molex: 19705 - 4301 2 x 6 - 32 inches pan head screw pin 1 = rtn pin 2 = v1 pin 1 = inhibit pin 2 = signal return pin 3 = vfan (+12 v) pin 4 = - remote sense pin 5 = vs/b (5 vdc) pin 6 = + remote sense pin 7 = signal return pin 8 = power good mating connector: molex: 09 - 50 - 3031 pins: 08 - 50 - 0106 mating connector: molex: 190030001 mating connector: 16 awg wire crimped to ring tongue terminal. amp: 8 - 31886 - 1 mating connector: molex: 22 - 01 - 2087, pins: 08 - 50 - 0113 copyright ? 2010 power - one inc. all rights reserved. words and logos that are identified as trademarks and/or service marks are, unless noted otherw ise, the trademarks and service marks of power - one inc. in the u.s. and other countries. all other product o r service names are the property of their respective holders. power - one products are protected under numerous u.s. and foreign patents and pending applications, maskwork rights, and copyrights. power - one reserves the right to make changes to any products a nd services at any time without notice. power - one assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by power - one inc. nuclear and m edical applications - power - one products are not designed, intended for use in, or authorized for use as critical components in life su p- port systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of power - one, inc. technical revisions - the appearance of products, including safety agency certi fications pictured on labels, may change depending on the date manufa c- tured. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of ABC300-1T24G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X